A ductulator is a special tool for HVAC pros. It helps size air ducts by considering airflow (CFM), duct type, friction rate, and velocity. It helps determine the correct duct dimensions (round or rectangular) to ensure efficient air distribution in heating and cooling systems. Ductulators can be slide tools or digital tools, like this online version. They provide quicker and more accurate calculations.
Using this digital ductulator is simple. No guesswork, no math headaches.
Start with your setup. Pick the type of duct you’re using: metal, ductboard, or flexible. This matters because each material handles airflow differently.
Choose how you want to size it. You can go by friction rate (how much air resistance happens in your system) or by velocity (how fast the air moves inside the duct). Think of it like choosing between road bumps or speed.
Plug in your values. Enter your friction rate and duct run length. Then, provide either the airflow (CFM) or the duct size—whichever you have ready first.
Pick your duct shape. Round or rectangular — each one affects how air flows, so choose what fits your design.
Hit calculate. The tool quickly displays your results. Airflow and speed numbers are highlighted, making them easy to see.
Need a conversion? Use the bottom section to switch between round and rectangular ducts. Just enter your dimensions, and it does the math for you.
Not all ducts breathe the same. Metal keeps its shape and airflow steady. In contrast, flex ducts ripple like an accordion, which traps static pressure. Ductboard? It’s quiet but slows the breeze. Each type has a different drag pattern, which changes how air pushes through.
Friction rate is like invisible resistance in the duct path. Higher friction means more push is needed to keep air moving. It’s like skating on ice versus sliding on carpet. Both use the same motion, but the effort differs. It directly affects how wide the duct needs to be to stay efficient.
Total Equal Length (TEL) isn’t how long your duct runs. It includes every turn, elbow, or boot — the full maze, not the hallway. TEL adds invisible distance to your airflow path, which adds strain. The longer the TEL, the harder your blower works to maintain flow.
CFM (Cubic Feet per Minute) is how much air your system needs to move. More CFM means a bigger path. It’s like needing a wider hose for higher water volume. If the duct is too small for the airflow, it chokes performance and gets noisy.
Air likes round paths. Rectangular ducts may fit ceilings better, but corners slow the wind. Shape isn’t about space; it changes the internal drag and affects velocity. Choosing round or rectangular changes how airflow performs through the run.
Some techs size by velocity, others by friction. Velocity-based sizing focuses on air speed; friction-based sizing controls pressure loss. Your choice of mode changes the duct size even if the airflow stays the same. One prioritizes silence, the other speed.
Flex vs rigid airflow resistance:
Flexible ducts act like a rippled tunnel, so air meets more bumps along its windway. Metal ducts stay smooth, cutting drag and letting the breeze glide with less push.
Static pressure loss comparison:
In a flex run, static pressure climbs quicker because of all the internal waves. A metal conduit holds pressure steadier, so your blower doesn’t have to crank as hard.
Drag effect in flexible ducts:
Flex linings have tiny ridges that grab on to moving air, slowing its roll. Every ripple creates mini eddies that eat up your blower’s energy.
Material-based system pressure:
Hard‑shell metal keeps the airway straight, so pressure drop is small. Softer materials like ductboard absorb pressure. This means you need wider paths to ensure proper airflow.
Why ridges cause drag
Think of running your hand over a washboard—each ridge fights against you. In flex ducts, those ridges add invisible hurdles for the air.
Real-world performance
On site, flex lines often need a boost to hit the same CFM as smooth steel. That means you’ll see lower airflow or higher noise if you don’t size up.
Adjusted values for flex airflow:
This tool tweaks its math to include flex drag, so your CFM readout matches real installs. You won’t end up with underpowered runs or wasted blower torque.
Better load matching:
The calculator considers material quirks. It matches airflow with your heating or cooling load just right. No more guessing how much breeze your flex run can carry.
Sizing for comfort zones
Living spaces usually need 300–400 CFM per 12‑inch flex run to keep rooms cozy. Larger runs can push up to 600 CFM without feeling windy.
Ranges by diameter
A 6‑inch flex line handles about 80–120 CFM, while 10‑inch jumps to 300–350 CFM. Diameter tweaks let you dial in just the right airflow.
Correct sizing steps:
Pick “flex” in the duct type menu, then type your inside diameter in inches. Hit calculate and see the airflow magic happen.
Avoiding common entry errors:
Don’t guess diameter—measure the inside tube, not the insulation wrap. Enter only the bare tube size for spot-on results.
Visual airflow references:
Our chart shows a line for each flex size, so you can eyeball CFM by reading across the grid. It’s like a map for wind capacity.
Diameter-to-CFM layout:
Along the top, you see duct inches; down the side, CFM steps. Find your size, then trace to the matching airflow number.
Target velocity range
Aim for 600–800 feet per minute in flex lines to keep noise down. Too fast, and you hear whistling; too slow, and air won’t reach the ends.
Avoiding noise and restrictions
Sticking in that sweet spot stops rattles and ensures even room temperatures. It’s the Goldilocks speed right for comfort.
A 12-inch round duct usually moves about 475 to 850 CFM, depending on how fast the air flows. If you’re running air around 600 feet per minute (FPM), you’re looking at roughly 625 CFM. But real-world numbers shift if the duct is flex instead of rigid, or if it’s squished behind a wall. Always check how smooth, straight, and stretched the duct is. If it sags or bends too much, cut the expected airflow by 15–30%.
For a 12×12 room, that’s 144 square feet. If you’re aiming for comfort, figure about 6–7 CFM per square foot in cooling mode. That gives you a target of 850–1,000 CFM total, but that’s shared across the whole system. One vent into that room? You’d typically run a 6″ or 7″ duct. Bigger rooms with sun-facing walls or upstairs heat gain may need a 7″ round duct. Insulated basements might be okay with a 6″.
The common shortcut is to aim for 0.1 to 0.08 inches of friction loss per 100 feet. That means balance between pressure and airflow. For quick field checks, consider a 6″ duct that handles about 100 CFM. Then, add or subtract about 100 CFM for every 2-inch change in diameter. Keep in mind, this is only a rough estimate. It shouldn’t take the place of a complete duct design that accounts for actual airflow needs and run length.
The 2-foot rule means keep flex duct pulled tight within every 2 feet of hang support. It’s not about airflow itself; it’s about avoiding air drag that results from drooping. When a flex duct drops more than 2 feet between supports, it forms ridges. Those ridges work like little air brakes. Result? Less CFM, more static pressure, and uneven room temps.
Neither is ideal, but undersized ducts cause more harm. When ducts are too small, air pressure builds up like water in a squeezed hose. That leads to loud vents, weak airflow, and overworked blowers. Oversized ducts? They cost more and might reduce air speed too much, but they rarely harm comfort. So if you have to guess, go a bit bigger—but never without checking system pressure.